Mode
AS-Interface
fault diagnostics
AS-Interface power
Set
AS-Interface
diagnostics/mode
K-bus diagnostics
Mode
AS-Interface+
AS-Interface-
Set
Mode
AS-Interface+
AS-Interface-
Set
Top view
Contact assembly
Mode
AS-Interface
fault diagnostics
AS-Interface power
Set
AS-Interface
diagnostics/mode
K-bus diagnostics
Power contact
ASi+
Power contact
ASi-
Mode
AS-Interface+
AS-Interface-
Set
Mode
AS-Interface+
AS-Interface-
Set
Top view
Contact assembly
KL6201, KL6211 | AS-Interface master terminals
The AS-Interface master terminal is an extended master according to profile M3 and enables the direct connection of AS-Interface slaves. The AS-Interface-compliant interface supports digital and analog slaves, versions 2.0 and 2.1, safety slaves and slaves with Combined Transaction Type 1 (profile S-7.3 and 7.4). Process data exchange, parameterisation and the diagnosis are fieldbus-independent. Together with the different Bus Couplers, the KL6201 or the KL6211 represent a universal AS-Interface/fieldbus gateway. Together with the BK3120, the PROFIBUS DP V1 services can be used for communication with the KL6201 or KL6211. Unlike the KL6201 AS-Interface master terminal, the KL6211 features power contacts. This enables direct connection to the AS-Interface supply via the KL9520 AS-Interface potential feed terminal or the KL9528 power supply terminal.
| Technical data |
KL6201 | KS6201 |
KL6211 | KS6211 |
| Technology |
AS-Interface |
| Number of channels |
1 |
| AS-Interface channels |
1 |
| Number of slaves |
31 for V 2.0, 62 for V 2.1 |
| Specification version |
AS-Interface V 2.0, V 2.1 |
| Slave types |
digital and analog |
| Diagnostics |
power failure, slave failure, parameterisation fault |
AS-Interface address assignment |
via configuration or automatic |
| Cycle time |
max. 5 ms (31 devices) |
| Connection |
2 lines via spring force technology |
| Current consumpt. K-bus |
typ. 55 mA (K-bus), approx. 60 mA (AS-Interface) |
| Current consumption power contacts |
– (no power contacts) |
typ. 60 mA + load |
| Electrical isolation |
500 V (AS-Interface/K-bus) |
| Power contacts |
no |
yes |
| Bit width in the process image |
selectable: 12 bytes, 22 bytes or 38 bytes, of which 6 bytes parameter interface |
| Configuration |
via fieldbus parameter interface, DP-V1 or Bus Coupler through KS2000 |
| Weight |
approx. 55 g |
| Operating/storage temperature |
0…+55 °C/-25…+85 °C |
| Relative humidity |
95 %, no condensation |
| Vibration/shock resistance |
conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission |
conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. class/installation pos. |
IP 20/variable |
| Pluggable wiring |
for all KSxxxx Bus Terminals |
| Approvals |
CE, UL, Ex |
CE, UL |
 |
 |
 |
| Special terminals |
|
| KL6201-0010 |
preset to 22 bytes K-bus interface (2 K-bus cycles 31 AS-Interface slaves) |
| KL6201-0011 |
preset to 38 bytes K-bus interface (4 K-bus cycles 62 AS-Interface slaves) |
 |
 |
| Accessories |
|
| KL9520 |
AS-Interface potential feed terminal with filter, 35 V DC |
| KL9528 |
AS-Interface power supply terminal 24 V DC, output 30 V DC, 1.25 A |
 |
 |
Product announcement |
KL6201, KL6211: available
KS6201, KS6211: estimated market release on request
|
 |
 |